PCR product clean-up with ExoSAP and preparation of samples for Sanger sequencing · version 1.1.1 (2026-11-20). Full protocol: EnGeL-MOLB-EXOSAP. Tick each step when done; write deviations in Notes.
| Date |
|
| Operator |
|
| Plate ID / samples |
|
| ExoSAP reagent lot |
|
| Sequencing order number |
|
Before starting
| ☐ |
• |
Clean the working space and material with bleach and water and leave the UV light on for at least 15 min. |
| ☐ |
• |
Use filter tips at all steps. |
| ☐ |
• |
Clean forceps and spatulas with 3% sodium hypochlorite and 96% ethanol between samples. |
1. Judge the PCR products
| ☐ |
1 |
Look at the gel image of each PCR product. Mark it as strong (clear, bright band) or faint (visible but weak band). Products without a single band of the expected size are not sent. |
2. Clean up the PCR products
| ☐ |
2 |
Mix 5 µL of PCR product with 2 µL of ExoSAP-IT Express on ice. |
| ☐ |
3 |
In the thermocycler: 37 °C for 4 min, 80 °C for 1 min, then hold at 4 °C. |
| ☐ |
4 |
Mix 5 µL of PCR product with 2 µL of ExoSAP-IT on ice. |
| ☐ |
5 |
Run the ExoSAP-IT programme (about 30 min in total) [TO CONFIRM: temperatures and times from the ExoSAP-IT user guide]. |
| ☐ |
6 |
Per sample, mix 1 µL SAP (1 U/µL), 0.25 µL Exonuclease I (20 U/µL) and 3.75 µL nuclease-free water, and add 15 µL of PCR product (20 µL in total). |
| ☐ |
7 |
In the thermocycler, with the heated lid switched off: 37 °C for 40–45 min, 80 °C for 15 min, then hold at 4 °C. |
3. Prepare the sequencing samples
| ☐ |
8 |
For each product and each primer, label a tube (or plate well) with the sample name of the order, following the provider’s instructions for tube type and labelling. |
| ☐ |
9 |
Pipette the cleaned product and water: |
| Strong |
1 µL |
4 µL |
| Faint |
2.5 µL |
2.5 µL |
| ☐ |
10 |
Add 5 µL of diluted primer (10 pmol). Total volume: 10 µL. |
| ☐ |
11 |
If more volume is needed, scale all three volumes by 1.5 (total 15 µL) [TO CONFIRM: when the 1.5× volumes are used]. |
| ☐ |
12 |
Close, spin briefly and keep at 4 °C (fridge) until shipping. |
4. Record and send
| ☐ |
13 |
Complete your sheet in the Sanger recording file (see Data and metadata) before the samples leave the lab. |
| ☐ |
14 |
Send the samples to the provider, following its current instructions for volumes, tubes and labels: |
| Eurofins |
Drop-off box at UC-Biotech; samples in a closed plastic zip-lock bag |
| StabVida |
Drop-off box at UC-Biotech; samples in a closed plastic zip-lock bag |
| Macrogen |
Pick-up service; a shipping label is generated for the shipment when needed |
After finishing
| ☐ |
• |
Clean the bench with 70% ethanol. |
| ☐ |
• |
Empty the small bench bin into the right waste bin. |
| ☐ |
• |
Wash your hands. |
| ☐ |
• |
Turn off equipment and lights. |
| ☐ |
• |
Lock doors, fridge and freezer. |
Notes / deviations