Bench sheet · EnGeL-FAUNA-MAR-MORPH

Sampling, MacFadyen extraction and sorting of soil microarthropods · version 1.1.1 (2026-11-20). Full protocol: EnGeL-FAUNA-MAR-MORPH. Tick each step when done; write deviations in Notes.

Date
Operator
Plate ID / samples
Ethanol 96% lot

Before starting

☐ No. Step
☐ • Define sampling points according to the sampling design of the study.
☐ • Register the samples in the sample master data file to obtain EnGeL labels (type of sampling Macf).

1. Collecting the soil samples

☐ No. Step
☐ 1 At each sampling point, use a split corer to collect a soil sample.
☐ 2 Open the corer. Optionally, take a photo of the soil core profile to complement the site characterisation.
☐ 3 Separate the sample inside the corer into the litter/organic layer (including the humus horizon; variable thickness is expected) and the mineral soil.
☐ 4 Discard the mineral soil in the split corer (mineral soil is collected with an additional PVC tube).
☐ 5 Record the depth of the litter layer.
☐ 6 Place the litter sample in a labelled plastic box (Annex 1).
☐ 7 For the undisturbed mineral soil, remove the litter layer to expose the mineral soil and take a core to a depth of 5 cm with a PVC tube (5 cm diameter × 5 cm height, c. 100 cm³).
☐ 8 Drive the PVC tube gently into the soil using a wooden or rubber block and a mallet, to avoid compacting the soil.
☐ 9 Remove the PVC tube from the soil with a spade placed underneath it. Remove excess soil around the tube with a knife.
☐ 10 Close both ends with plastic caps, seal them with paper tape to preserve the soil structure, and place the tube in a labelled plastic bag.
! CRITICAL Avoid disturbing the core structure and compacting the soil, which could kill the animals. The time between sampling and extraction should not exceed 5 days, to minimise effects of confinement and shifts in the micro-populations. Keep samples in an aerated space at room temperature until shipping.
☐ 11 For shipping, pack the samples in a styrofoam box.

2. Extracting microarthropods

☐ No. Step
☐ 12 In the laboratory, set up the MacFadyen extraction system.
☐ 13 Place each sample core upside down in a canister with a plastic or metal net (2 mm mesh) at the bottom.
☐ 14 Connect the canister to a funnel attached to a collecting flask containing 25 mL of 96% ethanol.
☐ 15 Build up a temperature difference of about 35–40 °C between the upper and lower parts: heat the upper part to 45–50 °C while cooling the lower part to a maximum of 10 °C (field temperature). Circulate heated air in the canister area and cooled air in the collecting area.
☐ 16 Increase the temperature of the upper part gradually, starting at about 5 °C above field temperature during the first 2–3 days, to prevent sample desiccation and animal death.
☐ 17 Then intensify the gradient (upper part 45–50 °C) for the remaining days. The total extraction time is 7 days.

3. Sorting and preserving

☐ No. Step
☐ 18 After extraction, label the animal samples for identification and prepare them for storage until sorting.
☐ 19 Place each sample in a Petri dish under the stereomicroscope.
☐ 20 Sort the animals into major groups and morphotypes according to life-form traits (pigmentation, antenna length, presence of ocelli, furca and scales/long hairs). Handle animals with a pipette or a fine brush.
☐ 21 Transfer each group/morphotype to a plastic vial with 96% ethanol and store at room temperature (ideally in the fridge if there is space) for molecular analyses.

After finishing

☐ No. Step
☐ • Clean the bench with 70% ethanol.
☐ • Empty the small bench bin into the right waste bin.
☐ • Wash your hands.
☐ • Turn off equipment and lights.
☐ • Lock doors, fridge and freezer.

Notes / deviations